FH Upper AustriaResearch & Development

Medical Technology Research Center Linz Campus

Publications

Unraveling the Macromolecular Pathways of IgG Oligomerization and Complement Activation on Antigenic Surfaces

J. Strasser, R. de Jong, F. Beurskens, G. Wang, A. Heck, J. Schuurman, P. Parren, P. Hinterdorfer, J. Preiner - Unraveling the Macromolecular Pathways of IgG Oligomerization and Complement Activation on Antigenic Surfaces - Nano Letters , 2019
IgG antibodies play a central role in protection against pathogens by their ability to alert and activate the innate immune system. Here, we show that IgGs…   mehr
  • Journal
  • Medical Engineering

Characterization of an Artificial Skull Cap for Cranio-Maxillofacial Surgery Training

M. Hollensteiner, D. Fürst, P. Augat, F. Schrödl, B. Esterer, S. Gabauer, S. Hunger, M. Malek, D. Stephan, A. Schrempf - Characterization of an Artificial Skull Cap for Cranio-Maxillofacial Surgery Training - JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, Vol. 29, No. 9, 2018
Cranial grafts are favored to reconstruct skeletal defects because of their reduced resorption and their histocompatibility. Training possibilities for…   mehr
  • Journal
  • Medical Engineering

Assessment of trabecular microstructure and mechanical properties in the intermediate cuneiform of healthy and diabetic patients using microcomputed tomography

S. Senck, P. Weißenbacher, J. Kastner, T. Reiter, S. Hofstaetter, K. Trieb, E. Kranioti - Assessment of trabecular microstructure and mechanical properties in the intermediate cuneiform of healthy and diabetic patients using microcomputed tomography - 8th World Congress of Biomechanics, Dublin, Ireland, 2018
  • Proceedings
  • Medical Engineering

3D Kinematics

T. Haslwanter - 3D Kinematics - Springer International Publishing, 2018
This book presents an introduction to the analysis of general movements in 3D space, especially for movements of the human body. It is based on the lecture…   mehr
  • Book
  • Medical Engineering

Characterization of polyurethane-based synthetic vertebrae for spinal cement augmentation training

M. Hollensteiner, M. Botzenmayer, D. Fürst, M. Winkler, P. Augat, S. Sandriesser, F. Schrödl, B. Esterer, S. Gabauer, K. Püschel, A. Schrempf - Characterization of polyurethane-based synthetic vertebrae for spinal cement augmentation training - Journal of Materials Science: Materials in Medicine, Vol. 29, No. 10, 2018
Purpose: Vertebral augmentation techniques are used to stabilize impacted vertebrae. To minimize intraoperative risks, a solid education of surgeons is…   mehr
  • Journal
  • Medical Engineering

Validation of a Simulator for Cranial Graft Lift Training: Face, Content, and Construct Validity

M. Hollensteiner, P. Augat, D. Fürst, B. Esterer, S. Gabauer, M. Malek, S. Hunger, F. Schrödl, A. Schrempf - Validation of a Simulator for Cranial Graft Lift Training: Face, Content, and Construct Validity - Journal of Cranio-Maxillo-Facial Surgery, Vol. 46, No. 8, 2018, pp. 1390-1394
Purpose: Surgical skills can be improved through practical exercise. The use of specimens, human as well as animal, or live animals for surgical training is…   mehr
  • Journal
  • Medical Engineering

X-ray-based Microstructural Analysis of Low Atenuaing Biocompaible Porous Materials under Simulated Physiological Condiions

D. Kytýř, P. Zlámal, P. Koudelka, T. Doktor, I. Kumpová, M. Vopálenský, P. Heimel, S. Mühleder, S. Senck - X-ray-based Microstructural Analysis of Low Atenuaing Biocompaible Porous Materials under Simulated Physiological Condiions - Proceedings of the 8th Conference on Industrial Computed Tomography, Wels, Austria (iCT 2018), Wels, Austria, 2018, pp. 1-7
  • Proceedings
  • Medical Engineering

Statistical analysis of 3D localization microscopy data for quantification of protein distribution upon clot formation

F. Hauser, S. Mayr, A. Tauscher, J. Jacak - Statistical analysis of 3D localization microscopy data for quantification of protein distribution upon clot formation - Proceedings of 8th Single Molecule Localization Microscopy Symposium, Harnack-Haus, Berlin, Germany, 2018
Extension of localization microscopy super-resolution methods to the third dimension as well as its multicolor application became state-of-the-art in the last…   mehr
  • Proceedings
  • Medical Engineering

Novel bone surrogates for cranial surgery training

M. Hollensteiner, D. Fürst, B. Esterer, P. Augat, F. Schrödl, S. Hunger, M. Malek, D. Stephan, A. Schrempf - Novel bone surrogates for cranial surgery training - J Mech Behav Biomed Mater, Vol. 72, No. 1, 2017, pp. 49-51
Parietal graft lifts are trained on human or animal specimens or are directly performed on patients without extensive training. In order to prevent harm to the…   mehr
  • Journal
  • Medical Engineering

Novel synthetic vertebrae provide realistic haptics for pedicle screw placement

M. Hollensteiner, P. Augat, D. Fürst, B. Esterer, S. Gabauer, K. Püschel, F. Schrödl, A. Schrempf - Novel synthetic vertebrae provide realistic haptics for pedicle screw placement - Proceedings of the PMU Science Get Together 2017, Nürnberg, Nürnberg, Germany, 2017
Objective During vertebral surgery, misplaced pedicle screws can harm vital neural and vascular structures1. Haptic distinction between cortical and…   mehr
  • Proceedings
  • Medical Engineering

Novel Simulator for Cranial Graft Lift Training

M. Hollensteiner, D. Fürst, B. Esterer, S. Gabauer, P. Augat, F. Schrödl, A. Schrempf - Novel Simulator for Cranial Graft Lift Training - Proceedings of the IAUP Triennial Conference, Wien, Austria, 2017, pp. 25-27
Cranial grafts are used for the reconstruction of skeletal defects after trauma, tumor, infection or congenital pseudarthrosis [1] and due to their…   mehr
  • Proceedings
  • Medical Engineering

Effect of alternating postures on cognitive performance for healthy people performing sedentary work

B. Schwartz, J. Kapellusch, A. Schrempf, K. Probst, M. Haller, A. Baca - Effect of alternating postures on cognitive performance for healthy people performing sedentary work - ERGONOMICS, Vol. 1, No. 40, 2017, pp. 778-795
Prolonged sitting is a risk factor for several diseases and the prevalence of worksite-based interventions such as sit-to-stand workstations is increasing.…   mehr
  • Journal
  • Media and Knowledge Technologies
  • Medical Engineering

Functional photoresists for sub-diffraction stimulated emission depletion lithography

R. Wollhofen, B. Buchegger, J. Jacak, J. Kreutzer, T. Klar - Functional photoresists for sub-diffraction stimulated emission depletion lithography - OPTICAL MATERIALS EXPRESS , Vol. 7, No. 7, 2017, pp. 1-23
Two novel photoresists were developed for the fabrication of sub-diffractionally sized polymeric nanostructures with chemically reactive surfaces. Using…   mehr
  • Journal
  • Medical Engineering

Bioinspired polymer microstructures for directional transport of oily liquids

C. Plamadeala, R. Wollhofen, J. Jacak, J. Heitz, T. Klar - Bioinspired polymer microstructures for directional transport of oily liquids - Royal Society Open Science, Vol. 10, No. 1098, 2017
Nature has always served as an inspiration for scientists, helping them to solve a large diversity of technical problems. In our case, we are interested in the…   mehr
  • Journal
  • Medical Engineering

Frequency domain optical resolution photoacoustic and fluorescence microscopy using a modulated laser diode

G. Langer, B. Buchegger, J. Jacak, T. Klar, T. Berer - Frequency domain optical resolution photoacoustic and fluorescence microscopy using a modulated laser diode - SPIE BiOS 2017 , San Francisco, United States of America, 2017
There is an increasing interest in functionalized complex 3D microstructures with sub-micrometer features for micro-and nanotechnology applications in biology.…   mehr
  • Proceedings
  • Medical Engineering

Multimodal fluorescence and photoacoustic microscopy in the frequency domain

G. Langer, B. Buchegger, J. Jacak, T. Klar, T. Berer - Multimodal fluorescence and photoacoustic microscopy in the frequency domain - SPIE BiOS 2017 , San Francisco, United States of America, 2017
  • Proceedings
  • Medical Engineering

3D STED lithography: Protein binding and non-binding

J. Kreutzer, B. Buchegger, J. Jacak, T. Klar, R. Wollhofen - 3D STED lithography: Protein binding and non-binding - SPIE BiOS 2017 , San Francisco, United States of America, 2017
  • Proceedings
  • Medical Engineering

Novel synthetic vertebrae provide realistic haptics for pedicle screw placement

M. Hollensteiner, P. Augat, D. Fürst, B. Esterer, S. Gabauer, K. Püschel, F. Schrödl, A. Schrempf - Novel synthetic vertebrae provide realistic haptics for pedicle screw placement - Proceedings of the 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Jeju, Republic of Korea, 2017, pp. 46-49
During vertebral surgery, misplaced pedicle screws can harm vital neural and vascular structures. Haptic distinction between cortical and cancellous bone…   mehr
  • Proceedings
  • Medical Engineering

Development and Validation of Bone Surrogates for Tabula Externa Graft Lift Training

M. Hollensteiner - Development and Validation of Bone Surrogates for Tabula Externa Graft Lift Training - Phd Thesis, Paracelsus Medizinische Privat Universität Salzburg, Austria, 2017
To avoid injuries of the patient during standard bone machining procedures a surgeon has to apply appropriate forces and speeds with the surgical instruments.…   mehr
  • Report
  • Medical Engineering

IMU-based solution for automatic detection and classification of exercises in the fitness scenario

C. Crema, A. Depari, A. Flammini, E. Sisinni, T. Haslwanter, C. Crema - IMU-based solution for automatic detection and classification of exercises in the fitness scenario - 2017 IEEE Sensors Applications Symposium (SAS), Glasboro, United States of America, 2017
  • Proceedings
  • Medical Engineering

Functional polymer scaffolds for biomolecule immobilization

J. Jacak, R. Wollhofen, T. Klar - Functional polymer scaffolds for biomolecule immobilization - SPIE Photonics Europe Proc., Brüssel, Belgium, 2016, pp. 1-6
  • Proceedings
  • Medical Engineering

Seite 1 von 3
FH Oberösterreich Logo